6200 N Hiawatha Ave 

6200 N HIAWATHA AVE, Chicago IL, 60646 Find on Google Maps (opens in a new tab)

Chicago Building ID: 138379

⚠️ This building did not report data in 2022, this data is from 2021, the latest year reported

Building Info

Square Footage
117,780 sqft
0.8x median
139,707 sqft
1/2 median Office
259,000 sqft
Built
1968
Primary Property Type
Office
Community Area
Forest Glen
Owner
Not Tagged

Emissions & Energy Information for 2021

Greenhouse Gas Intensity
0.4 kg CO2e / sqft
1/16 median
6.4 kg CO2e / sqft
1/17 median Office
6.9 kg CO2e / sqft
Total Greenhouse Gas Emissions
45.2 tons CO2e
1/20 median
885.8 tons CO2e
1/41 median Office
1,832.2 tons CO2e

Years Reported 5/5 A

  • 2018 data reported

    2018

  • 2019 data reported

    2019

  • 2020 data reported

    2020

  • 2021 data reported

    2021

  • 2022 data reported

    2022

Energy Breakdown

Natural Gas Use
0 kBtu
Median Chicago Building
5,818,399.6 kBtu
Median Office
2,672,800.1 kBtu
This Building Didn't Burn Any Natural Gas! 🎉

This building burned no natural gas on-site and isn't connected to a district heating system, meaning it's fully electric! View Chicago's Biggest Gas Free Buildings .

Electricity Use
316,374.2 kBtu
Est. Electric Bill: $13,000 for 2021**
1/12 median
3,796,376.7 kBtu
1/33 median Office
10,340,763.6 kBtu

Energy Mix

Total Energy Use: 316,374 kBTU

View Extra Technical Info
Source Energy Usage Intensity
7.5 kBtu / sqft
1/18 median
132.2 kBtu / sqft
1/19 median Office
142.6 kBtu / sqft
Site Energy Usage Intensity
2.7 kBtu / sqft
1/29 median
78.4 kBtu / sqft
1/25 median Office
66.3 kBtu / sqft

Full Historical Data Table

Year Floor Area sqft Chicago Energy
Rating
Energy Star
Score
GHG Intensity kg CO2e / sqft GHG Emissions metric tons CO2e Source EUI kBTU / sqft Electricity Use kBTU Natural Gas Use kBTU
2018 117,780 4.0 81 6.5769.7110.04,626,515-
2019 - 4.0 - ---
2020 117,780 4.0 100 1.0114.817.5735,380-
2021 117,780 4.0 100 0.445.27.5316,3740
2022 117,780 0.0 - ---

* Note on Rankings: Rankings and medians are among included buildings, which are those who reported under the Chicago Energy Benchmarking Ordinance for the year 2022, which only applies to buildings over 50,000 square feet.

** Note on Bill Estimates: Estimates for gas and electric bills are based on average electric and gas retail prices for Chicago in 2021 and are rounded. We expect large buildings would negotiate lower rates with utilities, but these estimates serve as an upper bound of cost and help understand the volume of energy a building is used by comparing it to your own energy bills! See our Chicago Gas & Electric Costs Source (opens in a new tab) for the original statistics.

Data Source: Chicago Energy Benchmarking Data (opens in a new tab)

What Should We Do About This?

Practically every building has room to improve with energy efficiency upgrades like insulation, switching to ENERGY STAR rated appliances, and more, but for any buildings with large natural gas use, we recommend one thing: electrify!

In other words, buildings should look to move all on-site uses of fossil fuels (including space heating, water heating, and cooking) to electrically powered systems like industrial grade heat pumps, heat pump water heaters, and induction stoves. With Illinois' current electric supply, just using the same amount of energy from electricity, rather than natural gas (aka methane) will dramatically reduce greenhouse gas emissions. This is because Illinois' grid in 2020 was already 67% carbon-free (see Illinois - Power | DecarbMyState (opens in a new tab)). This has already been done across the country with a variety of buildings, large and small, like the Hotel Marcel (opens in a new tab).

You can help make this a reality by talking to building owners and letting them know that a building's emissions are important to you, and that you want to see their building become fully electric and stop emitting greenhouse gases. Particularly for buildings you have a financial stake in (like your university, work, condo building, or apartment building) your voice in concert with your fellow building users can have a huge impact.

Additional Resources

See some additional resources on improving energy efficiency and understanding this data: